System Parameters & Dimensions
| Frequencies |
28, 30, 33,38, 50, 100, 200, 210 kHz; single or dual frequency; existing transducers can be used |
| Display of Data |
Color TFT display; Size 10.4", free selection of display layout; night & day presentation mode; optional on printer |
| Basic Scale Ranges |
10, 20, 50, 200, 500, 2000 m |
| Units |
Selectable: meters, fathoms ot feet |
| Measuring Accuracy |
Better than 2.5% of depth reading |
| Minimum Sounding Depth Below Transducer |
Approximately 0.5 m |
| Trim Correction |
5 m |
| Draft Correction |
Up to 29.9 m |
| Output Power |
150, 4450, 1000 W RMS, depending on transducer |
| Pulse Repetition Rate |
Max 180 pulses per minute |
| Gain Control |
Time Variable Gain (TVG) manual & automatic control for depth finding |
| Interfaces |
Output: DPT according to NMEA0183 & DIN EN 61 162-1
Input: NAV data according to NMEA0183 & DIN EN 61 162-1 |
| Environmental Conditions |
According to EN 60 945 |
| Operating Temperature |
-15° ... +55°C |
| Protection Code |
IP 53 |
| Power Supply |
90 - 260 V, 50 - 60 Hz; optionally 10 - 30 VDC |
| Power Consumption |
Approximately 35 W |
| Type Approval |
BSH Approval 6296 / 021 / 102 / Wheelmark |
| Weight |
6.1 kg |
| Dimensions |
288 (H) x 336 (W) x 150 (D) mm |
Special Features
- Recording of time and date internally generated
- Data output (depth values, etc.)
- Position if externally available
- Dead man alarm
- Mute control for acoustic alarm
Unit Dimensions